MPO & MTP High-Density Fiber Solutions for Scalable Data-Centre & Telecom Networks
MTP®/MPO Fiber Cabling Solutions: High-Density & Low Loss
Engineered for Zero-Error Migration: US Conec MTP® & Corning® Fiber
Don’t risk your data center uptime with generic MPO connectors. ABPTEL exclusively utilizes Genuine US Conec MTP® PRO connectors and Corning® ClearCurve® OM4/OS2 fiber.
Our “Elite Grade” trunks achieve an industry-leading 0.35dB Insertion Loss, ensuring you have enough optical budget for 100G SR4 and 400G SR8 hyperscale deployments.

QSFP to QSFP Direct Link
Scenario: Connecting two 40G/100G transceivers directly (e.g., Switch to Server). Selection: Female to Female, Type B (Crossover) Polarity. 💡 Engineer's Tip: Never connect Male to Male! Transceivers always have Male pins, so your cable MUST be Female.

MTP Cassette & Trunk
Scenario: Connecting two MTP Cassettes via a Trunk cable in racks. Selection: Female to Female (if cassettes are Male), Type A (Straight) or Type B (depends on design). 💡 Engineer's Tip: For Backbone trunks, Type A is standard, but you'll need an A-to-B patch cord at one end to flip polarity.

40G/100G to 10G/25G
Scenario: Splitting one QSFP port into 4x SFP+ ports (Top of Rack). Selection: MTP (Female) to 4x LC Duplex, Type B Polarity. 💡 Engineer's Tip: Check your transceiver type (SR4 vs PLR4) to ensure the fiber count matches (8 fibers vs 12 fibers).
Why Our MTP Cables Don’t Fail?
- ✔3D Interferometer Test: We test 100% of connectors for Radius of Curvature, Fiber Height, and Apex Offset. If the geometry isn’t perfect, physical contact fails.
- ✔US Conec MTP® Connectors: Unlike generic MPO connectors, genuine MTP® features a floating ferrule and elliptical guide pins to prevent fiber damage over 1000+ matings.
- ✔OFNP (Plenum) Jackets: All our US-bound cables use fire-retardant NFPA 262 plenum jackets for data center code compliance.
Fiber Count
Density
8, 12, 16, 24, 72 Fibers
Polarity
Method
Type A, Type B, Type C
Jacket Rating
Safety
LSZH (EU), OFNR (Riser), OFNP (Plenum)
Performance
Loss
Standard (0.5dB) vs Elite (0.35dB)
MPO / MTP Assemblies
Abptel, your trusted manufacturer in Shenzhen, delivers pre-terminated MPO® and US Conec MTP® cable systems that accelerate 40 G/100 G/400 G roll-outs while safeguarding tomorrow’s 800 G upgrades. Every trunk and harness is built under ISO 9001 and tested to IEC 61754-7 interface & IEC 61300-3-30 end-face geometry standards.
MTP® Elite ferrules guarantee ≤0.35 dB insertion loss and ≥55 dB return loss for single-mode optics.
MPO/MTP cabling consolidates 8 – 144 fibers in a single push-pull interface, slashing rack congestion and installation time versus traditional LC or SC termination. Typical use-cases:
* Spine-leaf fabrics in hyperscale data-centres
* 5G C-RAN & fronthaul backhaul links
* Disaster-recovery interconnects between Tier-2 DCs
* High-performance computing (HPC) & AI clusters
MPO/MTP High-Density Trunk Cable
12-144 fibers, ≤ 0.35 dB Elite IL; factory-terminated for spine-leaf backbones and rapid data-center roll-outs.
MPO/MTP Fan-Out Harness Cable
1× MPO/MTP to 4/6/12× LC (or CS/SN); ideal for TOR switch break-outs and panel consolidation.
MPO/MTP Breakout Patch Cord
8 F / 12 F compact patch leads that bridge parallel-optic ports to duplex LC optics inside tight racks.
MTP®-16F Ultra-Low-Loss Trunk
Next-gen 16-fiber MTP® Elite ferrule, ≤ 0.35 dB IL; ready for 400 G / 800 G DR4/FR4 deployments.
MPO/MTP Cassette Module
Plug-and-play module converts trunk cabling to LC front ports; supports polarity A/B/C field swapping.
1U / 4U High-Density Sliding Fiber Rack
Holds up to 48F (1U) or 96F (4U) of MPO cassettes; tool-less slide-out tray for fast MACs.
MPO/MTP Adapter Panel
12-, 24-, 32-port blank or loaded panels for quick add-on capacity in existing ODFs.
MPO/MTP Loopback Module
QSFP-DD / QSFP28 / SFP28 / MPO-12 test plugs with 0.5 dB or 1 dB loss options for burn-in and port diagnostics.
High-density MPO/MTP trunks simplify 400 G leaf-spine cabling
All You Need to Know About MPO/MTP Cables
Our assemblies are available with OS2 single-mode and OM3 / OM4 / OM5 multi-mode fibers.
Fiber Count: 8, 12, 16, 24, 32, 48, 72, up to 144F trunks
Elite Insertion Loss (IL): ≤ 0.35 dB (SM & MM)
Standard IL: ≤ 0.75 dB (SM) / ≤ 0.60 dB (MM)
Return Loss (RL): ≥ 55 dB (SM-APC) / ≥ 25 dB (MM-PC)
Fiber Performance
| Mode | Elite IL (dB) | Std IL (dB) | RL (dB) | Bandwidth / Reach |
|---|---|---|---|---|
| OS2 | ≤ 0.35 | ≤ 0.75 | ≥ 55 (APC) | 400 G DR4 – 10 km |
| OM5 | ≤ 0.35 | ≤ 0.60 | ≥ 25 | 100 G-SR4 / 400 G SR8 – up to 150 m |
Explanation
Low IL preserves link budgets for PAM4 optics.
High RL minimises reflectance-sensitive DR4 / FR4 transceivers.
Wide Bandwidth on OM5 enables SWDM for 100 G over a single duplex.
MPO/MTP Cable Structure & Materials
12-fiber MT ferrule (or 16-fiber for 400 G/800 G parallel): precision-moulded, guide-pin-aligned.
Aramid yarn strength members for 220 N–1000 N pull rating.
Jacket options: OFNR, OFNP, LSZH (EU CPR Cca-s1b,d1,a1 compliant).
Pulling eye & mesh factory-installed for one-man duct pulls.
Mechanical Performance
Tensile Strength: 220 N (fan-out) up to 1000 N (12F trunk)
Crush Resistance: 1000 N/100 mm – protects during ladder-rack installation
Minimum Bend Radius: 10×OD (static), 20×OD (dynamic); bend-insensitive fiber option available
Mating Durability: < 0.20 dB change after 500 cycles
Considerations When Buying MPO/MTP Solutions
| Factor | What to Check | Abptel Advantage |
|---|---|---|
| Polarity | Type A / B / C mapping, breakout sequence | Pre-labeled polarity & schematic in each reel |
| Gender & Keying | Pin-male vs pin-female, key-up/down | Mix-and-match pin kits, adapters included |
| Loss Budget | Elite vs Standard IL | MTP® Elite ≤ 0.35 dB verified, QR-coded report |
| Environment | Plenum / LSZH / outdoor rating | CPR Cca LSZH & IP-rated outdoor jackets |
| Compliance | IEC 61754-7, 61300-3-30, 61755-3-31 | Full 3-D geometry & IL/RL CSV supplied |
MPO/MTP Quality Control & Testing
100% 3D Pass
Every connector is tested for Radius of Curvature, Fiber Height, and Apex Offset. Why? To guarantee physical contact on all 12/16/24 fibers simultaneously.
400x Cleanliness
Automated inspection ensures Zero Scratches/Pits on the fiber core. A single dust particle can burn out a 400G port. We clean it so you don’t have to.
IL/RL Testing
We guarantee Return Loss (RL) > 60dB (for APC) to prevent signal reflection, which is critical for high-speed PAM4 modulation networks.
Why Choose MPO/MTP?
Plug-and-Play Modularity
- Factory-terminated trunks cut cabinet build time by up to **70 %** versus field termination.
Density Without Compromise
- Up to 3,456 fibers per 1U using 16F MTP® Pro cassettes – perfect for AI & HPC clusters.
Smooth Migration to 400G / 800G
- Simply swap transceivers; existing 8F → 16F trunks support parallel optic upgrades
Comparing MPO/MTP to LC Duplex Cabling
| Parameter | MPO/MTP Trunk | Traditional LC |
|---|---|---|
| Fiber Count / Port | 8 – 144 | 2 |
| Typical IL (low-loss) | 0.35 dB | 0.15 dB |
| Upgrade Path | Parallel optics 400 G / 800 G | Requires recabling |
| Rack Density | ★★★★★ | ★★ |
| Field Termination | Not required | Required |
Q1: What is the difference between MTP® and MPO?
MPO is the generic interface standard. MTP® is a high-performance MPO connector manufactured by US Conec. It has superior mechanical design (floating ferrule, removable housing) that ensures lower insertion loss and better durability. All ABPTEL Elite cables use MTP® connectors.
Q2: Should I choose Male (Pinned) or Female (Unpinned)?
It depends on what you are plugging into.
Plug into Transceiver (Optical Module): Use Female (Unpinned).
Plug into Patch Panel / Cassette: Usually Male (Pinned), but check the cassette spec.
Rule of Thumb: Always mate Male to Female. Never Male to Male (damage!) or Female to Female (no signal).
Q3: Which polarity do I need for 40G QSFP+ SR4?
For a direct connection between two 40G QSFP+ modules, you need a Type B (Female to Female) cable. This “crosses over” the transmit fibers to the receive fibers.
Testing & Accessory Essentials
Equip your data-centre cabling with the must-have tools and hardware that speed up installation, keep links spotless and make troubleshooting painless.
Loopback Module
MPO-12 / QSFP-DD / SFP-28 test plugs with 0.5 dB or 1 dB loss for quick port burn-in and diagnostics.
LC / SC Fixed Attenuator
3 dB, 5 dB and 10 dB ceramic units that fine-tune receive power without introducing extra connectors.
Fiber-Optic Cleaning Kit
100 cleaning sticks, lint-free wipes and IPA ribbon; removes dust and oil in seconds, supports MPO & LC.
PLC Fiber Splitter (ABS)
1×8, 1×16, 1×32 indoor modules with ≤ 0.2 dB uniformity, perfect for monitoring taps or FTTH aggregation.