MPO & MTP High-Density Fiber Solutions for Scalable Data-Centre & Telecom Networks

MTP®/MPO Fiber Cabling Solutions: High-Density & Low Loss

Engineered for Zero-Error Migration: US Conec MTP® & Corning® Fiber

Don’t risk your data center uptime with generic MPO connectors. ABPTEL exclusively utilizes Genuine US Conec MTP® PRO connectors and Corning® ClearCurve® OM4/OS2 fiber.

Our “Elite Grade” trunks achieve an industry-leading 0.35dB Insertion Loss, ensuring you have enough optical budget for 100G SR4 and 400G SR8 hyperscale deployments.

💎 US Conec Components 📉 0.35dB Low Loss
Comprehensive data center connectivity setup featuring OM4 fiber cables and QSFP transceivers for high-bandwidth network performance

QSFP to QSFP Direct Link

Scenario: Connecting two 40G/100G transceivers directly (e.g., Switch to Server). Selection: Female to Female, Type B (Crossover) Polarity. 💡 Engineer's Tip: Never connect Male to Male! Transceivers always have Male pins, so your cable MUST be Female.

ABPTEL MTP-12 OM4 Magenta Jumper Female to Female UPC 5m Type A

MTP Cassette & Trunk

Scenario: Connecting two MTP Cassettes via a Trunk cable in racks. Selection: Female to Female (if cassettes are Male), Type A (Straight) or Type B (depends on design). 💡 Engineer's Tip: For Backbone trunks, Type A is standard, but you'll need an A-to-B patch cord at one end to flip polarity.

ABPTEL OS2 Singlemode MTP-MPO-LC Cassette, 24 LC Duplex, LGX Method A (1)

40G/100G to 10G/25G

Scenario: Splitting one QSFP port into 4x SFP+ ports (Top of Rack). Selection: MTP (Female) to 4x LC Duplex, Type B Polarity. 💡 Engineer's Tip: Check your transceiver type (SR4 vs PLR4) to ensure the fiber count matches (8 fibers vs 12 fibers).

Why Our MTP Cables Don’t Fail?

  • 3D Interferometer Test: We test 100% of connectors for Radius of Curvature, Fiber Height, and Apex Offset. If the geometry isn’t perfect, physical contact fails.
  • US Conec MTP® Connectors: Unlike generic MPO connectors, genuine MTP® features a floating ferrule and elliptical guide pins to prevent fiber damage over 1000+ matings.
  • OFNP (Plenum) Jackets: All our US-bound cables use fire-retardant NFPA 262 plenum jackets for data center code compliance.
Detailed breakdown of MPO/MTP connector internal components.

Fiber Count

Density

8, 12, 16, 24, 72 Fibers

Polarity

Method

Type A, Type B, Type C

Jacket Rating

Safety

LSZH (EU), OFNR (Riser), OFNP (Plenum)

Performance

Loss

Standard (0.5dB) vs Elite (0.35dB)

MPO / MTP Assemblies

Abptel, your trusted manufacturer in Shenzhen, delivers pre-terminated MPO® and US Conec MTP® cable systems that accelerate 40 G/100 G/400 G roll-outs while safeguarding tomorrow’s 800 G upgrades. Every trunk and harness is built under ISO 9001 and tested to IEC 61754-7 interface & IEC 61300-3-30 end-face geometry standards.
MTP® Elite ferrules guarantee ≤0.35 dB insertion loss and ≥55 dB return loss for single-mode optics.

MPO/MTP cabling consolidates 8 – 144 fibers in a single push-pull interface, slashing rack congestion and installation time versus traditional LC or SC termination. Typical use-cases:

* Spine-leaf fabrics in hyperscale data-centres 

* 5G C-RAN & fronthaul backhaul links 

* Disaster-recovery interconnects between Tier-2 DCs 

* High-performance computing (HPC) & AI clusters 

Abptel MPOMTP High-Density Trunk Cable
MPO/MTP High-Density Trunk Cable

12-144 fibers, ≤ 0.35 dB Elite IL; factory-terminated for spine-leaf backbones and rapid data-center roll-outs.

MPO&MTP Fan-Out Harness Cable
MPO/MTP Fan-Out Harness Cable

1× MPO/MTP to 4/6/12× LC (or CS/SN); ideal for TOR switch break-outs and panel consolidation.

12core MPO MTP Breakout Patch Cord
MPO/MTP Breakout Patch Cord

8 F / 12 F compact patch leads that bridge parallel-optic ports to duplex LC optics inside tight racks.

40g Trunk Cable 12 Fiber Optic MTP MPO Patch Cord
MTP®-16F Ultra-Low-Loss Trunk

Next-gen 16-fiber MTP® Elite ferrule, ≤ 0.35 dB IL; ready for 400 G / 800 G DR4/FR4 deployments.

MPO/MTP Cassette Module
MPO/MTP Cassette Module

Plug-and-play module converts trunk cabling to LC front ports; supports polarity A/B/C field swapping.

1U~4U High-Density Sliding Fiber Rack
1U / 4U High-Density Sliding Fiber Rack

Holds up to 48F (1U) or 96F (4U) of MPO cassettes; tool-less slide-out tray for fast MACs.

MPO/MTP Adapter Panel

12-, 24-, 32-port blank or loaded panels for quick add-on capacity in existing ODFs.

MPO/MTP Loopback Module

QSFP-DD / QSFP28 / SFP28 / MPO-12 test plugs with 0.5 dB or 1 dB loss options for burn-in and port diagnostics.

High-density MPO/MTP trunks simplify 400 G leaf-spine cabling

All You Need to Know About MPO/MTP Cables

Our assemblies are available with OS2 single-mode and OM3 / OM4 / OM5 multi-mode fibers.

Fiber Count: 8, 12, 16, 24, 32, 48, 72, up to 144F trunks 

Elite Insertion Loss (IL): ≤ 0.35 dB (SM & MM) 

Standard IL: ≤ 0.75 dB (SM) / ≤ 0.60 dB (MM) 

Return Loss (RL): ≥ 55 dB (SM-APC) / ≥ 25 dB (MM-PC) 

MPO/MTP Fiber Optic Cable Manufacturing Process Overview

Fiber Performance

ModeElite IL (dB)Std IL (dB)RL (dB)Bandwidth / Reach
OS2≤ 0.35≤ 0.75≥ 55 (APC)400 G DR4 – 10 km
OM5≤ 0.35≤ 0.60≥ 25100 G-SR4 / 400 G SR8 – up to 150 m

Explanation

Low IL preserves link budgets for PAM4 optics.
High RL minimises reflectance-sensitive DR4 / FR4 transceivers.
Wide Bandwidth on OM5 enables SWDM for 100 G over a single duplex.

MPO/MTP Cable Structure & Materials

MPO/MTP Trunk Cables

12-fiber MT ferrule (or 16-fiber for 400 G/800 G parallel): precision-moulded, guide-pin-aligned.


Aramid yarn strength members for 220 N–1000 N pull rating.


Jacket options: OFNR, OFNP, LSZH (EU CPR Cca-s1b,d1,a1 compliant).


Pulling eye & mesh factory-installed for one-man duct pulls.

Mechanical Performance

Tensile Strength: 220 N (fan-out) up to 1000 N (12F trunk)


Crush Resistance: 1000 N/100 mm – protects during ladder-rack installation

Minimum Bend Radius: 10×OD (static), 20×OD (dynamic); bend-insensitive fiber option available

Mating Durability: < 0.20 dB change after 500 cycles 

Considerations When Buying MPO/MTP Solutions

Factor What to Check Abptel Advantage
Polarity Type A / B / C mapping, breakout sequence Pre-labeled polarity & schematic in each reel
Gender & Keying Pin-male vs pin-female, key-up/down Mix-and-match pin kits, adapters included
Loss Budget Elite vs Standard IL MTP® Elite ≤ 0.35 dB verified, QR-coded report
Environment Plenum / LSZH / outdoor rating CPR Cca LSZH & IP-rated outdoor jackets
Compliance IEC 61754-7, 61300-3-30, 61755-3-31 Full 3-D geometry & IL/RL CSV supplied

MPO/MTP Quality Control & Testing

MPO/MTP cables with testing and inspection equipment.

100% 3D Pass

Every connector is tested for Radius of Curvature, Fiber Height, and Apex Offset. Why? To guarantee physical contact on all 12/16/24 fibers simultaneously.

400x Cleanliness

Automated inspection ensures Zero Scratches/Pits on the fiber core. A single dust particle can burn out a 400G port. We clean it so you don’t have to.

IL/RL Testing

We guarantee Return Loss (RL) > 60dB (for APC) to prevent signal reflection, which is critical for high-speed PAM4 modulation networks.

Why Choose MPO/MTP?

Plug-and-Play Modularity

  • Factory-terminated trunks cut cabinet build time by up to **70 %** versus field termination.

Density Without Compromise

  • Up to 3,456 fibers per 1U using 16F MTP® Pro cassettes – perfect for AI & HPC clusters.

Smooth Migration to 400G / 800G

  • Simply swap transceivers; existing  8F → 16F trunks support parallel optic upgrades

Comparing MPO/MTP to LC Duplex Cabling

Parameter MPO/MTP Trunk Traditional LC
Fiber Count / Port 8 – 144 2
Typical IL (low-loss) 0.35 dB 0.15 dB
Upgrade Path Parallel optics 400 G / 800 G Requires recabling
Rack Density ★★★★★ ★★
Field Termination Not required Required
Q1: What is the difference between MTP® and MPO?

MPO is the generic interface standard. MTP® is a high-performance MPO connector manufactured by US Conec. It has superior mechanical design (floating ferrule, removable housing) that ensures lower insertion loss and better durability. All ABPTEL Elite cables use MTP® connectors.

It depends on what you are plugging into.

  • Plug into Transceiver (Optical Module): Use Female (Unpinned).

  • Plug into Patch Panel / Cassette: Usually Male (Pinned), but check the cassette spec.

  • Rule of Thumb: Always mate Male to Female. Never Male to Male (damage!) or Female to Female (no signal).

For a direct connection between two 40G QSFP+ modules, you need a Type B (Female to Female) cable. This “crosses over” the transmit fibers to the receive fibers.

Testing & Accessory Essentials

Equip your data-centre cabling with the must-have tools and hardware that speed up installation, keep links spotless and make troubleshooting painless.

10Gtek 25G SFP28 Loopback Module
Loopback Module

MPO-12 / QSFP-DD / SFP-28 test plugs with 0.5 dB or 1 dB loss for quick port burn-in and diagnostics.

LC SC Fixed Attenuato
LC / SC Fixed Attenuator

3 dB, 5 dB and 10 dB ceramic units that fine-tune receive power without introducing extra connectors.

Fiber-Optic Cleaning Kit

100 cleaning sticks, lint-free wipes and IPA ribbon; removes dust and oil in seconds, supports MPO & LC.

Fiber Optic PLC Splitter ABS Box
PLC Fiber Splitter (ABS)

1×8, 1×16, 1×32 indoor modules with ≤ 0.2 dB uniformity, perfect for monitoring taps or FTTH aggregation.

CONTACT US

Need any urgent help? to hire us now!

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Call For Booking

+86 18814455697

Have A Questions ?

Candy@abptel.com

Location Address

5/F, Building 10, Tangwei Cuihai Industrial Zone, Fuyong Town, Baoan District, Shenzhen

Get a free quotes

Need a Quick Quote?

Just Leave Your Message, Contact You Within 2 Hours! 

× How can I help you?